An ssr has side joints between the roof panels that are arranged in a vertical position above the roof line.
Low slope copper roof.
The minimum roof slope for metal roof panels depend on 3 different scenarios.
Low slope metal roofs have simple geometries and are easier and less expensive to install that medium to steep slope roofs.
Lapped nonsoldered seam metal roofs without applied lap sealant must have a minimum roof slope of 3 12 25 slope.
For a long span roof utilizing multiple seamed pan lengths transverse seams are required.
First the metal must be cut down to pans no larger than 18 by 24 inches so thermal expansion and contraction won t overstress the solder joints.
Instead only sections such as towers porches bay windows and low slope sections copper with soldered seams get copper for looks or waterproofing purposes.
See example table 8 8a.
These panels generally come with a painted mill finish or a clear acrylic finish.
These are soldered interlocking systems of metal panels.
Flat seam roofing systems are typically used on roofs that are flat or have a low pitch or alternatively on very steep slopes.
Low slope roofs are not totally flat their roof slope generally ranges from 1 4 12 to 3 12.
Copper and stainless steel can be used for low slope roofs but a fair amount of planning is involved.
For roof slopes less than 6 on 12 the upper roof pan is attached to a locking strip soldered to the lower pan.
Flat seam roofing is constructed of 18 by 24 20 oz.
Rectangular cold rolled copper sheets.
Low slope metal panel roofing may be a standing seam roof ssr through fastened roof tfr or insulated metal panel imp roof.
Low slope structural roofing generally used on roof pitches ranging from 12 to 3 12 consists of interlocking panels commonly called standing seam roofing that run vertically along the roof surface.
Today it is rather rare that an entire roof gets covered with copper.
The lower pan is cleated to the roof deck with the indicated clearances determined by expansion calculations.
This means for every 12 horizontal units the roof must rise a minimum of 3 vertical units.
Traditionally low slope or flat roofs would use a built up tar and gravel roof but today this traditional type of roofing suffers from performance cost environmental concerns requiring better value solutions.
They are also used on curved surfaces such as domes and barrel vaults.